Scene elements reference

Last updated November 16, 2026

Elements are what you place on a view: fire, smoke, victims, apparatus, hazards, hydrants, fire department connections, drop tanks, water sources, openings, and ground ladders. This page covers placing them and every setting each type has.

Placing and manipulating#

  1. Click a tool in the toolbar: Fire, Smoke, Victim, Apparatus, Hazard, Hydrant, FDC, Drop tank, Water source, Opening, or Ladder. Drop tank and Water source appear on the aerial only. An opening is drawn corner by corner rather than placed with one click. Ladder appears once the scenario has ground ladders turned on.
  2. Click the scene where it goes.
  3. Select an element by clicking it. Its settings appear in the right panel.
Action How
Move Drag it.
Resize Scroll over it.
Turn The Rotation slider in the inspector, for victims and apparatus. A ladder is leaned with the handle at its tip instead.
Delete Select it and press ⌫, or use Delete element in the inspector.

Elements belong to the view they were placed on. Place fire on Side B and it is visible from Side B only. Build each side to show what is actually visible from that position.

Apparatus, hydrants and FDCs are not offered on interior views. There are no rigs or water supply inside the structure. Ladders are offered on exterior photographs only.

Fire#

Setting Range Meaning
Stage Smoldering, Incipient, Growth, Fully developed, Flashover How advanced the fire is when the drill starts.
Growth per minute 0.00 to 2.00 How fast it advances on its own during the drill.
Cast light on the scene On or off Whether the fire lights the photograph around it.
Color Deep red to yellow What the flame burns at.
Brightness 0 to 100% How hot it reads, up to a white core.

Growth is per minute of exercise time. At 0.00 the fire stays where you set it, which is what you want when an inject or a level is going to drive the escalation instead. At 0.30 it advances roughly one stage every three minutes. At 1.00 or higher it runs away quickly, which is useful for a scenario about recognizing a losing fight.

Color and brightness#

These are a tactical signal, not decoration. A fire that is short of air burns red: a contained compartment fire seen through a window, or one behind a door that has not been opened yet. A fire with plenty of air burns yellow, and turned up, white at its core, which is what a fully involved free-burning fire looks like.

So a fire you have contained inside an opening usually wants to be redder and dimmer than the same fire venting out of it. Building both, and letting the crew tell you which they are looking at, is the point of having the controls.

The range stops at yellow deliberately. Past it a flame turns green, which is not a thing a building fire does.

Existing scenarios are unaffected: these values were always in the renderer, just not adjustable, and the defaults are exactly what they were.

Cast light#

With it on, the fire throws warm light onto the wall, the window frame and the ground near it, and that light breathes with the flames. It is what makes a fire read as being in the building rather than drawn on top of the picture. It comes up with the stage, so a smoldering fire barely glows and a fully developed one lights its surroundings, and it dims when a crew knocks the fire down.

New fires have it on. Fires built before September 2026 have it off, and stay off until you tick the box. That is deliberate: a drill that has already been run replays from its own copy of the scenario, and its after-action review has to show what the crew actually saw rather than being relit afterwards.

Turn it off for a fire that should not be throwing light on what you can see, such as one deep inside a structure lighting a room the view cannot reach.

Fire also produces smoke on its own; you do not need to add smoke to a fire for it to look like something is burning. Add smoke separately when you want to control what shows from a given side.

See Fire and smoke behavior over time for what happens once the clock runs.

Smoke#

Setting Range Meaning
Density 0.0 to 4.0 How much smoke is produced.
Darkness 0.00 to 1.00 How black it reads, from light gray to near black.
Color any color The tint the smoke carries. Neutral by default.
Lit from below by fire On or off Whether the fire beneath this plume glows on its underside.

Color is there because what smoke looks like is part of what a crew is being asked to read, and because a hazmat drill needs smoke that is not gray.

Lit from below#

Every photograph of a working fire has it: the belly of the lower billows glows, and it fades out as the column climbs away from what is feeding it. With this on, the lower part of the plume catches warm light from beneath, each billow catches it a little differently, and the whole column breathes together, because one fire is feeding it.

This one is off by default, including on new smoke, which is the opposite of a fire's cast light. A fire always lights its own surroundings, so that can be assumed. Smoke is only lit from below when something is burning below it, and only you know whether this plume is the one over the fire or the one drifting across the far side of the building.

It has no effect on an aerial or terrain view, where the column lays out downwind rather than climbing, so the setting is not offered there.

Choosing a color#

Click the color button to open the picker. It has three ways in, and they all set the same value:

  • The square sets how strong and how bright the color is. Drag anywhere in it.
  • The hue slider under the square runs through the spectrum. It works with the arrow keys once focused.
  • The hex field takes an exact value, if you are matching something.

Click anywhere outside the picker, or press Escape, to close it.

The swatches under the button are shortcuts to common tints, one click each. They are a starting point, not a limit: pick one and then open the picker to adjust it.

Color and Darkness together#

They are separate controls and both apply. Darkness sets how black the smoke goes; color sets the tint it carries on the way there. So a mid brown at a high darkness comes out very dark brown, close to black, and the same brown at a low darkness reads clearly as brown.

The round chip beside the picker shows what the smoke will actually look like at the darkness you have set, so you can see the two together before you place it. If a color is coming out darker than you expected, the Darkness slider is what to reach for.

Neutral is the default, and a scenario that never touches this control looks exactly as it always did.

What the colors mean#

That is yours to teach. The swatches are named for the color only, and a scenario carries no interpretation of them.

On an exterior view, smoke rises and drifts as a plume. On an interior view it behaves like smoke in a room instead: overlapping banks that churn and roll in place while visibility drops from the ceiling down. Dense, dark interior smoke approaches blackout, which is intentional: reporting conditions you can barely see through is the exercise.

Placed smoke also follows a knockdown. Once every fire on its view has water on it, the smoke converts to white steam over about twenty seconds (with a surge in volume, since steam is more, not less), then thins to nothing over the next three minutes. Anything the instructor authors later wins: a situation level or a hand edit fired after the knockdown shows exactly as set. See Fire and smoke behavior over time.

Victim#

Setting Options
Who Adult, Older adult, Child, Wheelchair user, Infant. A wheelchair user and an infant are non-ambulatory by nature, so they have one figure and open as down.
Status Ambulatory, Down, Rescued. Rescued keeps the figure as it was, standing or down, and adds a green shield over it: the scene keeps showing what the crew found.
Rotation 0 to 359 degrees, so a down victim can lie across a doorway or slump into a corner the way the room suggests.

Each kind and pose has its own figure, and none of them carry a label: the artwork says it. Down is a victim on the floor. Ambulatory and Down wear a red halo so they stay findable against a light wall or a bright roof; Rescued does not, because the halo means somebody is still in there.

Rescued marks one already removed, which is useful when you are staging a scenario mid-incident, and it is also what an instructor sets during a drill the moment a crew carries someone out.

Victims are visible to whoever can see the view they are on, so a victim at a rear window is information a crew has to earn by walking around.

Apparatus#

Setting Options
Responding unit Which unit this rig is, chosen from the scenario's own units. Leave it on Scenery (no crew) for a rig that is only set dressing.

Set the responding unit on any rig you want to run a supply line to. A supply line connects things the drill knows about, so a rig that is scenery cannot take one: arm the Supply line tool, click it, and nothing happens. The element panel says so on any rig still set to scenery, and the toolbar says what is connectable while the tool is armed.

Scenery is a real and useful setting. It is for the rig parked down the block that nobody responds in.

Rigs start at their real size on a fetched aerial. The aerial knows how much ground it covers, so a rig placed on it is drawn its real length: an engine about 33 feet, a ladder truck about 44, a tanker about 35, a brush truck about 23, a battalion chief's SUV about 17. Changing the Type of a rig you have not resized moves it to the new type's size. Scroll to resize it anyway; Reset scale puts it back. An uploaded aerial has no ground scale, so its rigs start at a standard size. | Type | Engine, truck (aerial), rescue, medical, tanker, brush, hazmat, command, police, UTV, boat, drone | | Callsign | Free text, for example E52 | | Rotation | 0 to 359 degrees: which way the rig is pointed. On an overhead photo that is how it sits in the street. |

Every type has its own photograph, drawn to a common height so their relative lengths stay honest: an aerial reads longer than an ambulance, which reads longer than a UTV, because that is how they are. Scroll to size a rig to the photo.

Naming the responding unit matters on an aerial. With the apparatus placement module off, the side of the structure a rig is parked on is the side its crew arrives looking at, and the only way the drill knows whose rig it is is the unit you picked here. Picking one also fills in the type and callsign from the unit, so the two cannot disagree. See Module: apparatus placement.

With the module on, do not place apparatus at all: the crews park their own as they arrive.

Hazard#

Setting Meaning
Label Text shown on the scene, for example Propane tank or Downed line.

Use hazards for anything a crew should size up and report: utilities, storage, exposures, access problems.

Hydrant#

Setting Options
Status In service, Out of service

Place hydrants where they actually sit on the street so crews have to find them and command has to plan water supply around them. An out of service hydrant renders dimmed with a red slash and an OUT OF SERVICE label, which is a useful curveball: nothing announces it, so a crew has to walk to it and report the problem, and command has to find water somewhere else. During a drill, crews and the instructor lay supply lines between hydrants and rigs on the aerial, and the lay goes in the record; an out-of-service hydrant refuses the hookup. To open a drill with a line already laid, use the Supply line tool on the aerial: click one end, click along the route, click the other end. See Apparatus placement in a drill.

Hydrants are exterior only.

Drop tank#

For a district with no hydrants: the portable tank the tenders dump into and an engine drafts from. Place it on the aerial where it would be set up. On an aerial fetched in the builder it starts at its real size, about 14 feet on its long side; scroll to resize it and Reset scale to put it back. Set Rotation to square it to the road or to wherever the tenders can back up to it.

During a drill a drop tank takes two lines: two engines drafting from it, or a line on to a second drop tank. Its other end is a rig or another drop tank, never a hydrant or a water source.

You do not have to place every tank in advance. With apparatus placement on, crews on an engine or a tanker set their own during the drill, and so can the instructor: see Drop tanks.

Water source#

A pond, a stream, a cistern or a dry hydrant: water the crew can draft from. Place it on the aerial; it shows as a pin.

Setting Options
Name the crew sees Shown under the pin, such as "Farm pond". Optional.
Status In service, Out of service

A water source takes any number of lines, each from a rig. An out of service one (a dry pond, a frozen dry hydrant) renders dimmed with a red slash and refuses every line, the same curveball as a dead hydrant. During a drill the instructor can add one through Change conditions on the aerial, and the crew sees it when it is pushed.

Fire department connection#

The FDC tool places the connection's sign where it sits on the building, on an exterior view or on the aerial. It has the same in service and out of service setting as a hydrant, and an out-of-service one renders dimmed with a red slash.

During a drill, anyone who can lay a supply line on the aerial can hook a line from a rig to the FDC. It is a siamese, so it takes two lines, one per inlet, and only from a rig: a hydrant does not connect to it directly. Only an FDC placed on the aerial can be hooked; one in a street photograph is there to be seen.

Opening#

An opening is a window, a door or any gap in a wall that a fire or its smoke is inside. It lets you author a fire showing at a window rather than venting out of it, and smoke banked behind the glass, and then lets the fire break out of the opening as it grows.

Drawing one#

  1. Click Opening in the toolbar. It is offered on photographs of the building, not on an aerial, where there is no wall to put one in.
  2. Click each corner of the window in turn: at least three, up to 24.
  3. Click the first corner again, or press Close shape. Undo point takes back the last corner and Cancel abandons the shape.

From the keyboard: with the tool chosen, the arrow keys move a marker, Enter drops a corner, Backspace removes the last one, and Esc abandons the shape.

The outline shows in the builder only. Crews see what the opening does to the fire, never the shape. An opening goes into every situation level by itself, so a level never drops it mid-drill and lets its fire escape by accident.

Putting a fire or smoke inside it#

Select the fire, or the smoke, and choose the opening under Contained by. Not contained puts it back. The control appears once the view has a finished opening. The light a contained fire casts still reaches past the opening and onto the wall, the way it does through glass.

What happens as the fire grows#

The fire's stage decides it, so a situation level or a change you make during the drill moves it along, and a knockdown takes it back.

Fire stage What the crew sees
Smoldering to Growth The fire shows at the window and stays inside it. Smoke starts leaving almost at once, thin at first and thickening, from every edge of the opening: pushed out, then rising.
From halfway between Growth and Fully developed Flame starts out of the top of the opening, a narrow stream that widens as the stage climbs.
A little past Fully developed The opening vents all it can. The part of the fire outside burns like any other; the part still inside stays inside, with its smoke behind the glass.

Smoke leads the flame by a long way on purpose. A room pushes smoke through every gap while the fire is still well inside, and that is the cue crews read from the street, long before flame shows.

Ground ladder#

Ladders are for talking through ladder placement: which window, which side, how far it is raised, and how steep it stands. Turn them on for a scenario with the Ground ladders checkbox on the Setup tab. The Ladder tool then appears on exterior photographs. It is not offered on an aerial, terrain, or interior view, because there is no wall there to lean one on.

The ladder is a two-section extension ladder. Click where its foot goes, at the base of the wall, and it stands there bedded and upright. Then:

Action How
Raise and lean it Drag the yellow handle at its tip. It raises a whole rung at a time, the way a fly locks on a rung, and stops at full extension.
Move it Drag the ladder. It moves from wherever you took hold of it.
Make it look nearer or farther Scroll over it, or press + and -. The foot stays where it is and the ladder grows or shrinks from it.
Setting Options
Seen from The front, or the side.
Flip Mirrors a ladder seen from the side, putting the fly on its other side. The button says which side the fly is on.
Fly extended Bedded, up to 9 rungs out.
Lean Up to 80 degrees left or right of straight up.

Seen from the side is for a ladder against a wall the camera sees edge on. You see one rail, the rung ends along it, and the fly riding beside the bed. It is the only view that shows how steep the ladder stands. Flip mirrors it, the same as flipping a rig, which puts the fly on the other side of the bed. Switching between the front and the side keeps the ladder where it is, as far out, and as steep.

There is one ladder rather than a choice of lengths: raise it with the fly and size it to the photograph by scrolling. Nothing measures whether it reaches. A photograph has no true scale, so that is for the crew to talk through.

During a drill, crews see the ladders you placed and cannot move them. The instructor can move, raise and lean them while composing a new situation, the same as any other element. Crews also throw ladders of their own during the drill; a new one starts the size of the ladder you placed on that photo, so placing one there sets how big a ladder looks against it. See Throwing ground ladders.

Fire perimeter (wildland)#

Setting Meaning
Spread direction Compass heading the fire is running toward (0 = north)
Length, feet Heel to head, real feet on the ground
Width, feet Across the flanks
Flame length, feet At the head: the number every wildland check reads

The perimeter is the wildland scene element, offered on a georeferenced terrain view in a wildland scenario, because its numbers are real feet: the point you click is the heel, and the fire runs the authored length along the spread direction to the head, drawn with a burned interior, a dull heel edge, and a glowing head.

As you set the flame length, the panel reads back the IRPG fire behavior class and what it means tactically: 4 to 8 feet is already too intense for handtools, and past 8 feet control efforts at the head are ineffective (IRPG PMS 461, 2025). Resizing it, by scroll or with + and -, edits the real footprint in feet rather than applying a multiplier.

Grow the fire by capturing situation levels: each level snapshots the perimeter's size and position, so firing levels in sequence walks the fire across the map.

Practical notes#

  • Size matters for readability. An element scaled too small on a wide image is easy to miss on a phone screen.
  • Everything you place here is the starting condition. The instructor can change any of it live during the drill, and situation levels let you prepare whole rearrangements ahead of time.
  • Fewer, well-placed elements read better than a scene covered in them. Crews should have to look.